Descriere
The first semi-automatic cable blowing unit with blowing assistant and electronic blowing data memory. Now in series production.
The new IntelliJet is a pioneering, intelligent blowing system that facilitates the blowing of fibre optic mini cables for the operator and improves installation quality. Cable layers as well as clients benefit from these improvements.
At the heart of the innovation is the measurement, presentation and control of the pushing force, which is transferred onto the cable by the drive system. The pushing force is constantly verified against the maximum permissible pushing force, which is determined through the crash test, and which will be specified in the cable data sheet in the future. A second assistant monitors the cable slippage. Both assistants give the operator an indication as soon the blowing procedure approaches a critical range and provide information on counter-measures. If the critical range is exceeded, the blowing unit stops. In this way, damage to cables can be avoided, the responsibility of the blow-in operator is relieved and the blowing quality is increased.
A clear blowing log with an electronic data transfer completes the new system. The new IntelliJet not only helps meet the minimum requirements for automatic logging of Deutsche Telekom but also the far-reaching demands for automated blowing processes. In addition to the new device, the IntelliJet can also be created from the tried and tested „MiniJet” blowing unit by means of an upgrade. With the IntelliJet, sustainability for further automation levels is also guaranteed. The main benefits for cable layers are:
- Operators with little blowing experience can also achieve optimal blowing results with sensitivity and technical skill – the problem with the currently tight labour market can thus be alleviated.
- The two blowing assistants indicate critical operating conditions and stop the blowing procedure before damage to the cable occurs.
- Time savings for the blowing team and in order processing thanks to automatic data logging, archiving and electronic transmission.
- The logging of blowing parameters can provide evidence of bad subduct routes and is thus a basis for legitimate variation orders.
- The handling on the construction site is simple and nearly identical to current work with the MiniJet.
- Customers also benefit from the use of the IntelliJet:
- The automation of the blowing process will improve blowing performance and quality and reduce damage to cables, which increases the efficiency of FTTx projects.
- Precise and clear logging of the agreed blowing performance facilitates the error detection, financial settlement and data archiving.
- If damage to cables occurs at a later point, the original blowing log provides a reference for the blowing-out capability of the cable and can thereby reduce the repair time required (simplification of crisis scenario).
- Always both positions IntelliJet (Pi 02 OB) and IntelliBox (IBN 02) must be ordered!
Code | Type | C-D | Duct-D | Air-supply | Push | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
424302 | PI 02 OB | 4-12 | 8-40 | 16 bar/5 m³/min. | 300 N | 47,00 | |||||||
424342 | IBN 02 | 13,00 |
A customer MiniJet of the P01 and P02 (from 2011) series can be upgraded at Vetter to the IntelliJet version. An „upgrade” machine such as this has no disadvantages compared with the new device when put to practical use on the construction site.
Upon customer request, during this upgrade the condition of the MiniJet can also be checked at the same time, a maintenance offer issued, if necessary, and carried out on acceptance of the service. In this way, the overhauled, newly upgraded IntelliJet blowing unit will once again be well prepared for the upcoming challenges of the various blowing projects.
- Always both positions IntelliJet Upgrade Set (PIU OB Upgrade) and IntelliBox (IBN 02) must be ordered!
Code | Type | C-D | Duct-D | Air-supply | Push | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
424330 | PIU OB Upgrade | 4-12 | 8-40 | 16 bar/5 m³/min. | 300 N | 3,10 | |||||||
424342 | IBN 02 | 13,00 |
MiniJet, further development of the CableJet and MicroJet. For blowing-in mini fibre optic cables in long distances. Long and soft pneumatic belt drive especially for delicate cables. Produces high daily output. Electronic length and speed meter. Without cable and duct inserts. accessory and technical details see below.
- Very careful but high power transmission to the cable through the soft belts.
- Suitable excellent for very long cable distances with complicated design.
- Simple control, high safety for operator and for cable.
- Small dimension of 635x400x255, weight of the machine only 21,6 kg
- For compressed air to max. 16 bar, airflow to 5 m³/min.
Code | Type | C-D | D-OD | Air max. | Push | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
420100 | P 02 | 4-12 | 8-40 | 16 bar/5 m³/min. | 300 N | 41,00 |
Code | Type | C-D | In duct-D | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
420130 | SET 40-83 | 4,0-8,3 | 10 + 12 | 0,57 | ||||||||||
420140 | SET 84-124 | 8,4-12,4 | 14 + 16 | 0,56 |
Code | Type | D-OD | kg | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
420228 | REM 20 | 20 | 0,20 | |||||||||||
420230 | REM 25 | 25 | 0,20 | |||||||||||
420232 | REM 32 | 32 | 0,20 | |||||||||||
420240 | REM 40 | 40 | 0,20 |
Code | Type | D-OD | For device | Set | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
42230167 | RAD 07 | 7 | PRM196/EM25/P02 | 6 | 0,01 | |||||||||
42230168 | RAD 08 | 8 | PRM196/P02 | 6 | 0,01 | |||||||||
42230170 | RAD 10 | 10 | PRM196/P02 | 6 | 0,01 | |||||||||
42230172 | RAD 12 | 12 | PRM196/P02 | 6 | 0,01 | |||||||||
42024014 | RAD 14 | 14 | PRM196/P02 | 6 | 0,01 | |||||||||
42024016 | RAD 16 | 16 | IntelliJet/MiniJet | 6 | 0,01 | |||||||||
42024020 | RAD 20 | 20 | IntelliJet/MiniJet | 6 | 0,01 | |||||||||
42024025 | RAD 25 | 25 | IntelliJet/MiniJet | 6 | 0,01 | |||||||||
42024032 | RAD 32 | 32 | IntelliJet/MiniJet | 6 | 0,01 | |||||||||
42024040 | RAD 40 | 40 | IntelliJet/MiniJet | 6 | 0,01 |
Code | Type | C-D | For device | Set | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
42230147 | KAD 43 | 3,4-4,3 | PRM196/P02/NBK483 | 6 | 0,01 | |||||||||
42230149 | KAD 53 | 4,4-5,3 | PRM196/P02/NBK483 | 6 | 0,01 | |||||||||
42230151 | KAD 63 | 5,4-6,3 | PRM196/P02/NBK483 | 6 | 0,01 | |||||||||
42230152 | KAD 70 | 6,4-7,0 | PRM196/P02/NBK483 | 6 | 0,01 | |||||||||
42230154 | KAD 77 | 7,1-7,7 | PRM196/P02/NBK483 | 6 | 0,01 | |||||||||
42230156 | KAD 83 | 7,8-8,4 | P 02 / NBK 483 | 6 | 0,01 | |||||||||
42021509 | KAD 107 | 8,4-10,7 | P02 / NBK812 | 6 | 0,01 | |||||||||
42021511 | KAD 124 | 10,8-12,4 | P02 / NBK812 | 6 | 0,01 |
Lubricator L 9 for continuous greasing of the cables blown by MicroJet, MiniJet and UltimaZ. Performance and techn. details see below.
- The Lubricator guarantees an uniform lubrication on the whole length duct length.
- To mount on MiniJet there are adapters, see below.
- In the Lubricator is included an adapter for the MicroJets EM 25, PR 140 and PRM 196
Code | Type | Suitable to | C-D | D-OD | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
423500 | L 9 | MiniJet+MicroJet | 1-9 | 4-16 | 2,20 |
For lubrication unique and ultimate classification, Water pollution class – non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
Code | Type | Pack. drums | kg | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
234975 | MJL 240 | 1 bottle 0,24 l | 0,32 | |||||||||||
234977 | MJL 424 | 24 bottles 0,24 l | 7,50 |
Code | Type | D-OD | D-ID | Cellular | Qty. | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
275398 | RSM 04 | 7 | 4 | D 8×30 | 20 pcs. | 0,01 | ||||||||
275400 | RSM 06 | 7-10 | 5-6 | D 12×30 | 20 pcs. | 0,01 | ||||||||
275402 | RSM 08 | 10-12 | 8 | D 16×50 | 20 pcs. | 0,02 | ||||||||
275404 | RSM 10 | 12-16 | 10-12 | D 20×50 | 20 pcs. | 0,03 | ||||||||
275406 | RSM 16 | 20 | 15-16 | D 32×50 | 20 pcs. | 0,06 |
Code | Type | C-D | D-OD | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
275700 | NBK 483 | 3,4-8,3 | 7-16 | 1,40 | ||||||||||
275703 | NBK 812 | 8,4-12,4 | 12-20 | 1,50 | ||||||||||
275710 | DAP 08 | Air connector | for NBK 483 | 0,50 | ||||||||||
275712 | DAP 11 | Air connector | for NBK 812 | 0,73 |
Code | Type | D-OD | For device | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
423530 | RES 4 | 4 | Lubricator L 9 | 0,04 | ||||||||||
423532 | RES 5 | 5 | Lubricator L 9 | 0,04 | ||||||||||
423534 | RES 7 | 7 | Lubricator L 9 | 0,03 | ||||||||||
423536 | RES 8 | 8 | Lubricator L 9 | 0,03 | ||||||||||
423538 | RES 10 | 10 | Lubricator L 9+Intermed. blowing head | 0,03 | ||||||||||
423540 | RES 12 | 12 | Lubricator L 9+Intermed. blowing head | 0,03 | ||||||||||
423542 | RES 14 | 14 | Lubricator L 9+Intermed. blowing head | 0,03 | ||||||||||
423544 | RES 15 | 15 | Lubricator L 9+Intermed. blowing head | 0,03 | ||||||||||
423546 | RES 16 | 16 | Lubricator L 9+Intermed. blowing head | 0,03 | ||||||||||
423548 | RES 20 | 20 | Intermediate blowing head | 0,03 |
Code | Type | D-OD | For device | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
042353801 | RDL 4 | 4 | Lubricator L 9 | 0,01 | ||||||||||
042353802 | RDL 5 | 5 | Lubricator L 9 | 0,01 | ||||||||||
042353803 | RDL 7 | 7 | Lubricator L 9 | 0,01 | ||||||||||
042353804 | RDL 8 | 8 | Lubricator L 9 | 0,01 | ||||||||||
042353805 | RDL 10 | 10 | Lubricator L 9+Intermed. head | 0,01 | ||||||||||
042353807 | RDL 12 | 12 | Lubricator L 9+Intermed. head | 0,01 | ||||||||||
042353809 | RDL 14 | 14 | Lubricator L 9+Intermed. head | 0,01 | ||||||||||
042353810 | RDL 15 | 15 | Lubricator L 9+Intermed. head | 0,01 | ||||||||||
042353811 | RDL 16 | 16 | Lubricator L 9+Intermed. head | 0,01 |
The new pressure test device combines three test methods in one electronic device. General test rules” individual selectable acc. requirements from the customer – The requirement from Deutsche Telekom acc. „ZTV-TKNETZ 40” – The low-pressure test acc. EN 1610:2015 as well as worksheet DWA-A-139:2009
The high-pressure test is presently the most frequent test method in the range of pressure tests for protective ducts. This test method will be performed at thick-walled protective ducts and subducts (micro ducts). With regards to the protective ducts, ducts with OD 50/40/32 mm are most frequently used application. For subducts a wider range of ducts can be tested from 7×1,5 until 20×2,5 mm. The high-pressure test distinguish between two different targets:
- Verification of optimal blowing-in performance, which is guaranteed only by a pressure-tight duct system (short-term target)
- Assurance of pressure-tight duct, the joints and connectors against water intrusion and the subsequent intrusion of soiling with sand. This results in incrustations, which causes problems during the blowing-in process and possibly later at blowing-out of cables (long-term target)
Code | Type | Explanation | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231700 | High pressure | See the following devices | 0,00 |
The DPG 17U Universal pressure test device for test of cable ducts with regards to protective ducts and subducts working in the range of 0…7 bar. The operation is made by a 7″ colour-graphic-touch display. The new device support the user through a simple and menu-driven operation. With the help of a matrix (table) three different test methods can be selected. Those are „General test rules” individual selectable acc. requirements from the customer, the requirement from Deutsche Telekom acc. „ZTV-TKNETZ 40” and the low-pressure test acc. „EN 1610:2015”. This results in a maximum support for the user.
The result of the pressure test is summarized in a clear test protocol with three core areas. The test protocol will be stored on the device and can be loaded by a USB-interface to a customary PC.
The left shown 1. protocol shows a passed test „Test criteria fulfilled”
The left shown 2. protocol shows a failed test „Test criteria not fulfilled”
- Upper area: General data like: Contracting company with name of operator, construction site, duct, temperature, times, measurement data with calibration status
- Middle area: Result of the pressure test through colour-marked message: „Test criteria fulfilled” or „Test criteria not fulfilled”
- Lower area: Graph with the two phases settling time and main test
Code | Type | Designation | Press. | Application | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231740 | DPG 17U | Universal pressure test device | 0-7 bar | Cable conduits | 6,40 |
Pressure test distribution units for high-pressure tests of 1 duct acc. network level NE2 and NE3.
This test method will be performed at thick-walled protective ducts and subducts (micro ducts). With regards to the protective ducts the 50×4,6 duct is the most frequently used application. For subducts a wider range of ducts can be tested from 7×1,5 until 20×2,5 mm. For the connection of the ducts the right accessories have to be used to perform the test.
Code | Type | Designation | Connections | Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
23163007 | DPV 1 | Air distribution | 1 | 0-10 bar | 11,30 |
Pressure test distribution units for high-pressure tests of 1-4 ducts acc. network level NE2 and NE3.
This test method will be performed at thick-walled protective ducts and subducts (micro ducts). With regards to the protective ducts the 50×4,6 duct is the most frequently used application. For subducts a wider range of ducts can be tested from 7×1,5 until 20×2,5 mm. For the connection of the ducts the right accessories have to be used to perform the test.
Code | Type | Designation | Connections | Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2316293 | DPV 4 | Air distribution | 4 | 0-10 bar | 43,00 |
Pressure test distribution units for high-pressure tests of 1-12 ducts acc. network level NE2 and NE3.
This test method will be performed at thick-walled protective ducts and subducts (micro ducts). With regards to the protective ducts the 50×4,6 duct is the most frequently used application. For subducts a wider range of ducts can be tested from 7×1,5 until 20×2,5 mm. For the connection of the ducts the right accessories have to be used to perform the test.
Code | Type | Designation | Connections | Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231680 | DPV 12 | Air distribution | 12 | 0-7 bar | 52,00 |
Code | Type | D-OD | Press. | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231686 | AKR 07 | 7 mm | 0-7 bar | 0,02 |
Code | Type | D-OD | Press. | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
275750 | DAK 10 | 10 mm | 0-7 bar | 0,39 | ||||||||||
275752 | DAK 12 | 12 mm | 0-7 bar | 0,41 | ||||||||||
275754 | DAK 14 | 14 mm | 0-7 bar | 0,40 | ||||||||||
275756 | DAK 16 | 16 mm | 0-7 bar | 0,40 |
Code | Type | D-OD | Press. | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2316512 | KRA 20 | 20 mm | 0-7 bar | 0,40 | ||||||||||
23165140 | KRA 25 | 25 mm | 0-7 bar | 0,46 |
Code | Type | For subduct | To device | Max. Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231690 | AKS 10 | D 10 mm | DPV 12 | 0-7 bar | 0,13 | |||||||||
231691 | AKS 12 | D 12 mm | DPV 13 | 0-7 bar | 0,13 | |||||||||
231692 | AKS 14 | D 14 mm | DPV 14 | 0-7 bar | 0,14 | |||||||||
231693 | AKS 16 | D 16 mm | DPV 15 | 0-7 bar | 0,15 | |||||||||
231694 | AKS 20 | D 20 mm | DPV 16 | 0-7 bar | 0,21 |
Code | Type | For subduct | Max. Press. | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
272552 | ESM 05 | D 5 mm | 0-7 bar | 0,03 | ||||||||||
272556 | ESM 07 | D 7 mm | 0-7 bar | 0,01 | ||||||||||
272560 | ESM 10 | D 10 mm | 0-7 bar | 0,01 | ||||||||||
272562 | ESM 12 | D 12 mm | 0-7 bar | 0,02 | ||||||||||
272564 | ESM 14 | D 14 mm | 0-7 bar | 0,03 | ||||||||||
272568 | ESM 16 | D 16 mm | 0-7 bar | 0,02 | ||||||||||
272572 | ESM 20 | D 20 mm | 0-7 bar | 0,02 |
Code | Type | For | Together with | Max. Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231633 | PMK 10 | DPV 1+DPV 4 | KRA 20-110 | 0-7 bar | 0,70 |
Code | Type | For | Together with | Max. Press. | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231696 | PME 10 | DPV 12 | AKS 10-20 | 0-7 bar | 0,41 |
Case for accessory of high pressure test devices, without parts, with 12 shelves as following:
- 10 cases each 132x82x105 mm
- 1 case of 168x131x105 mm
- 1 case of 286x168x105 mm
Code | Type | Dimension | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231698 | KZD 6040 | 600x400x155 mm | 4,35 |
The calibration sets MKV 0810 and MKV 1116 in conjunction with the accessory micro- transmitter SKS 6 (code-no. 231941) are destined for the calibration of subducts with an internal diameter 8,0 to 16,0 mm. The calibration can be done for single subducts as well as for multi subducts. By the calibration defects or blockages on the subducts can be detected in advance thus a good blowing-in performance can be achieved.
The MKV 0810 set contains two calibres with different diameters for the calibration of subducts with internal diameter 8,0 or 9,8-10,0 mm. The MKV 1116 set contains three different calibres for testing subducts of ID 11,4-16,0 mm. The calibres are easily screwed onto the micro-transmitter and blown through the subducts by air-pressure. The set also contains all essential connectors, reducing nipples as well as a catcher for the micro-transmitter. The catcher has to be used in order to avoid damages to the micro-transmitter. The air-pressure for the calibration has to be limited to max. 4 bars for MKV 0810 and to max. 2 bars for MKV 1116. By applying a higher pressure the micro-transmitter might be damaged by hitting duct blockages or by hard crashing into the catcher at the very end. The set contains the following parts:
- MKV 0810 with: each 3 calibre D 6,8 for ID 8,0 / 3 calibre D 8,5 for ID 9,8-10
- MKV 1116 with: each 3 calibre D 9,5 / ID 11,4-12 / 3 calibre D 11,0 / ID 15-16 / 3 calibre D 12,5 / ID 15-16.
- 6 washers to each calibre
- 5 sponges for each calibre. 1 general catcher and different connectors and duct-reducers
- Depending on the duct diameters different air connectors are necessary, see the following tables.
Code | Type | Device | Subduct-ID | Case | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231950 | MKV 0810 | Calibration set | 8-10 | 180x140x80 | 1,43 | ||||||||
231952 | MKV 1116 | Calibration set | 11,4-16 | 442x357x151 | 5,00 | ||||||||
231941 | SKS 06 | Micro transmitter | D 6,5×84 | – | 0,17 | ||||||||
231943 | BAT 06 | Set of batteries | 10 each | – | 0,04 |
The calibration set MKK 0606 in conjunction with the micro transmitter SKS 04 is foreseen to calibrate subducts with inner diameter D 6.0 mm only. The calibration can be performed for single subducts as well as for multi subducts in buried and protective pipe installed versions. This new calibration set supports the blowing-in of mini- and micro cables on a completely new level since the quality of a sub duct installation can be checked in general.
The set comprises of 3 calibres with protection sponge having a diameter of 4.8 mm, a collecting device for the pipe end, a spare battery cover and 2 spare batteries.
The calibre will be simply unscrewed on the micro transmitter and with the sponge ahead blown-into the pipes using compressed air. The micro transmitter is a precision engineered measuring device, which has to be handled in the civil engineering with special care. Never operate the transmitter without protection sponge, bumper and collecting device fixed at the end of the pipe. Attentions should be paid to max. possible bending radius and air injection pressure – too high air pressure can cause damages on the calibration set.
During backward blowing the enclosed collecting device has to be used or at least a sufficient padding of another collecting device shall be implemented.
- Calibration set MKK 0606 including 3 calibres D 4,8 for ID 6,0 mm
- 20 sponges and collecting device at the pipe end for collection of the calibre
- 1 Micro Transmitter SKS 04, detection frequency 33 kHz, sensitivity in earth max. 2,0 m
- Max. injection pressure 5 bar, 4 bar is sufficient for horizontal routes
- Min. bending radius for subducts 175 mm, smaller radius cause unavoidable a blockage
- Batteries of the larger micro transmitter SKS 06 are used
Code | Type | Device | Subduct-ID | Case | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231930 | MKK 0606 | Calibration set | 6,0 | 180x140x80 | 1,00 | ||||||||
231943 | BAT 06 | Set of batteries | 10 pcs. | – | 0,04 |
Code | Type | Device | Subduct-ID | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231941 | SKS 06 | Micro transmitter | from 8 | 0,17 | ||||||||||
231943 | BAT 06 | Battery set | – | 0,04 |
Locating device with 2 batteries, for locating blown-in calibres in cable protection pipes or in subducts (micro pipes), as well as for locating non-metallic pipelines and blockages with the pipe coils, yellow or red D 4.5-11. There are the following possible applications:
- For detecting blocked calibre in cable conduits or in subducts
- Yellow conduit rod with screwed on duct transmitter RD 18 for spot detection
- Red conduit rod with screwed on duct transmitter RD 18 for spot detection
- Red conduit rod to transmitted by CAT SEN4, for line detection.
- Red ORS with CAT SEN4 and screwed on transmitter RD 18 for line and spot detection.
Code | Type | Frequency | Transmitter | L/W/H mm | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
231611 | CAT4+ | 33 kHz, | without | 255/70/725 | 2,80 |
Cable unwinder for small drums, even with damaged flanged wheels for electric installation works. Tubular steel construction galvanized. Consisting of: basic frame with 2 rubber coated wheels, one drum shaft D 25 mm with 2 cones of polyamide for hole diameter 25-80 mm.
- Collapsible for easy transportation to the site.
- Easy movable with the drum through big rubber coated wheels.
- For drum-D to 800 and drum widths to 530, drum weight max. 200 kg
- As accessory steel tube drum shaft D 50, ball bearings, 2 clamps, for cones see table below.
Code | Type | Equipment | Shaft | Cones for | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
320290 | KTA 8 | Winder as above | D 25 | Hole D 25-80 | 11,60 | ||||||||
320292 | KTA 8W | Steel tube shaft | D 50 | See next line | 2,05 | ||||||||
315504 | ZKP 50-80 | Poly-cone (1 each) | D 50 | Hole-D 50-80 | 0,15 | ||||||||
3155045 | ZKP 50-108 | Poly-cone (1 each) | D 50 | Hole-D 50-108 | 0,39 |
Drum unwinding stand for FOC or subduct drums, galvanized. Equipped with a lightweight aluminium shaft D 75 mm with drum shaft securing and 2 clamps.
- Sturdy steel construction, hot galvanized, easy dismountable by hand for transportation.
- Two crank spindles to lift the stand for unwind cables in any position.
- High stability under load even in uneven places.
- For drum-D to 1400, and drum width to 900, drum weight max. 500 kg.
- As accessory alu-drum shaft D 50, ball bearings, order clamps and cones separately, see table below.
- Dimensions mounted: L/W/H 1450/1400/689.
Code | Type | Equipment | Shaft | Cones for | kg | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344355 | TRG 1140 | Winder as above | D 75 | – | 96,00 | ||||||||
350592 | TAK 5013 | Alu drum shaft | D 50 | – | 7,40 | ||||||||
315030 | KSV 51 | Shaft clamps | D 50 | – | 1,30 | ||||||||
315504 | ZKP 50-80 | Poly-cone (1 each) | D 50 | Hole-D 50-80 | 0,15 | ||||||||
3155045 | ZKP 50-108 | Poly-cone (1 each) | D 50 | Hole-D 50-108 | 0,39 |
FigarinO. The FOC basket is used if the cable is to long to be blown completely with only one blowing machine. When half of the cable is installed in one direction the remaining cable is pushed into the FigarinO with the blowing machine. Out of the FigarinO this part of the cable can be blown uncut in the opposite direction to finish the installation.
A second application is „overblowing” longer cables. Instead of laying these on figure of eight on the floor they can be blown in the FigarinO. After opening the FigarinO the cable ring can be turned around and the cable can be blown-in totally.
- Cable Cap.: 4600 m D 4 / 2000 m D 6 / 1200 m D 7,5.
- The FigarO replaces laying figure of 8 on the ground, is clean and space saving.
- The FigarinO is always placed besides the cable drum.
Code | Type | Basket-D | For transport | kg | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
411150 | SLK 120 | 1260 | Divisible in the middle. | 71,00 |
Code | Type | Equipment | Suitable to | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
04111521 | KEB 120 | Cable bow | IntelliJet+MiniJet-FigarinO | 3,90 | ||||||||||
04111523 | KEB 120M | Cable bow | Intelli-MicroJet-FigarinO | 4,00 |
High powered compressors for blowing-in bigger fibre optic cables. Suitable for MiniJet, for duct ID up to 41 mm. Mounted on single axle trailer with height adjustable drawbar, without overrun brake.
- Hatz Diesel-engine, 42 kW. Compressor dimension: 4000x1540x1445 mm.
- Flow rate 3,8 m³, at 14 bar working pressure
- With integrated after cooler and water separator.
- Air discharge valve: 2 x G 3/4″
Code | Type | Air | Press. | D-ID | C-D | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
960123 | M 59 | 3,8 m³/min. | 14 bar | 3-16,0 | to 10 | 906,00 |
High powered compressors for blowing-in bigger fibre optic cables. Suitable for MiniJet, for duct ID up to 20 mm. Mounted on single axle trailer with height adjustable drawbar, without overrun brake.
- Kubota Diesel-engine, 17,9 kW. Compressor dimension: 3245x1260x1330 mm.
- Flow rate 1,6 m³, at 14 bar working pressure.
- With integrated after cooler and water separator.
- Air discharge valve: 2 x G 3/4″ (shown with option EVK 34)
Code | Type | Compr. air | Press. | D-ID | C-D | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
960120 | M 27 | 1,60 m³/min. | 14 bar | 3-16,0 | bis 10 | 600,00 |
Compressor with petrol engine and after cooler. For blowing-in fibre optic mini cables, fibres and bundle fibres. Suitable for all MicroJets and for MiniJet P 02. The external after cooler reduces the compressed air temperature approx. 8° C above ambient temperature. The compressor is equipped with a sound absorption cover. It is portable by two pneumatic wheels.
- With Honda-petrol engine 16 kW. Dimension: 1080x800x790
- Flow rate 1000 l/min. at 15,0 bar working pressure.
- With separate after cooler electrical feeded by the compressor. Air discharge valve: 1 x G 3/4″
- As accessory see tiltable support for after cooler, table below.
Code | Type | Air | Press. | D-ID | C-D | kg | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
960118 | MK 17.3 | 1,0 m³/min. | 15 bar | 3-12,0 | 0,8-9,0 | 206,00 |
Support for the after cooler on compressor MK 17.2. Steel frame hot galvanized. With this the after cooler is fixed safe and rubbery-elastic by four elements.
To transport the compressor in a van the after cooler is tiltable, please mind the total height of approx. 1,10 m. The after cooler can easily be dismounted from the support.
- Dimension with vertical positioned after cooler, L/W/H 1170/800/1220
- Dimension for transportation with tilted after cooler, total height only 1100
Code | Type | Material | kg | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
960145 | KHN 17 | Steel profiles, galvanized | 8,50 |